DC-Coupled On-Grid Solution
DC-Coupled On-Grid Solution
Designed for C&I enterprises and industrial parks undertaking new integrated PV-storage projects, this solution converges PV and energy storage onto a common DC busbar, which is inverted and grid-connected through a shared PCS. The system comprises a PV array, DC/DC converters, storage battery, PCS, EMS, and a monitoring platform. PV is stepped up via DC/DC converters and fed into the busbar, while storage connects directly; the two share the inversion stage, reducing conversion stages and improving efficiency and economics.
Core Values
Fewer Conversion Stages for Higher Efficiency Shared PCS for Lower Cost Unified Dispatch for Efficient Coordination
Pain Points
- ● Efficiency Loss from Multi-Stage Conversion: In AC coupling, PV and storage each invert independently, resulting in multiple AC-DC conversions and significant cumulative losses.
- ● High Equipment Investment Cost: PV inverters and storage PCS are configured separately, requiring more equipment and footprint, with high initial investment and O&M costs.
- ● Complex System Coordination: Multiple independent inverters operating in parallel make control coordination difficult, and joint PV-storage dispatch response is less direct.
- ● Low Integration for New Projects: If new PV-storage projects adopt AC coupling, AC connections must be designed separately, resulting in insufficient integration.
Application
| Typical Scenario | Electricity Consumption Characteristics |
|---|---|
| New Integrated PV-Storage Projects | PV and storage planned simultaneously; suitable for unified design of DC busbar and inversion system |
| High-Efficiency Requirement Scenarios | Sensitive to overall efficiency; seeking to reduce conversion losses and improve generation utilization |
| Land-Constrained C&I Projects | Limited installation space; requires higher equipment integration and reduced footprint |
Basic Requirements
1. The project is a new or DC-side-reconfigurable integrated PV-storage project, with PV and storage planned simultaneously.
2. A grid connection point of sufficient capacity, with access conditions confirmed by the utility.
3. Stable communication network for EMS data acquisition and monitoring.
Capacity, configuration, and connection method shall be determined based on on-site assessment.
Solutions
Design Highlights
This solution adopts a DC-coupled architecture: PV is stepped up via DC/DC converters and fed into a common DC busbar, while storage connects directly; the two are paralleled on the DC side. The DC busbar is inverted and stepped up via the PCS before connecting to the grid. The EMS uniformly collects PV, storage, and grid signals, coordinating DC/DC and PCS operation to achieve unified PV-storage power allocation.
- 1. Operating Strategy: PV outputs regulated voltage to the busbar via DC/DC, prioritizing inversion for grid feed-in or charging the storage; storage charges and discharges directly on the busbar, sharing the PCS with PV; during peak hours, storage discharges for joint output, while surplus PV charges the storage during off-peak hours. The system remains grid-connected at all times.
- 2. Configuration Confirmation: PV capacity is determined by installation area and load, with DC/DC converters configured by PV groups; storage capacity is designed based on peak-valley arbitrage demand; the total PCS power must cover the maximum simultaneous output of PV and storage; the connection method is confirmed in consultation with the utility.
System Connection Architecture
- 1. Generation Side (DC): The PV array connects to DC/DC converters via DC cables, and after stepping up, feeds into the common DC busbar.
- 2. Storage Side (DC): The storage battery connects directly to the DC busbar via DC cables, in parallel with PV.
- 3. Grid-Connection Side (AC): The DC busbar is inverted to AC by the PCS, stepped up via a transformer, and connected to the grid.
- 4. Communication Side: The EMS connects to DC/DC converters, storage, PCS, and the monitoring platform via communication lines, collecting data and issuing commands; data is uploaded to the cloud for multi-terminal monitoring.
Product Composition
The functions of each component are described below with reference to the topology diagram. Actual supply scope, product models, and features are subject to the project proposal.
| Component | Function |
|---|---|
| PV Array | Converts solar energy into DC electricity; the system's generation source |
| DC/DC Converter | Steps up and regulates voltage to DC busbar level; implements PV MPPT control |
| Storage Battery | Connects directly to the DC busbar; stores and releases electricity |
| DC Busbar | DC power aggregation point for PV and storage; the two are coupled in parallel here |
| PCS + Transformer | Inverts DC to AC and steps up for grid connection; shared inversion stage for PV and storage |
| Energy Management System (EMS) | Collects full-chain data; coordinates DC/DC and PCS operating strategies |
| Monitoring Platform | Operation monitoring, data querying, and alarm management; supports multi-terminal access |
| Utility Grid | Grid connection point for power exchange and voltage support; not included in supply scope |
Values
Improved Overall System Efficiency
PV and storage share the PCS inversion stage, and storage charge/discharge eliminates one conversion stage, reducing cumulative losses. Efficiency gains shall be calculated based on equipment parameters and operating conditions.
Reduced Equipment Investment Cost
DC/DC converters replace independent PV inverters, and the PCS is shared by PV and storage, reducing equipment count and footprint. Savings ratio shall be calculated based on project scale and quotations.
More Efficient PV-Storage Coordination
The DC busbar enables unified power dispatch, with a shorter EMS control chain and more direct joint PV-storage response, facilitating peak-valley arbitrage and power smoothing.
Project Cases
Case 1 | South Africa 300kWp 300kWh Agricultural Solar Microgrid
Project Name & Location: South Africa 300kWp 300kWh Agricultural Solar Microgrid, South Africa
Commissioning Date: March 2024
System Scale: 300 kWp PV Array; 150 kW MPS Hybrid Inverter; 300 kWh Lithium-Ion Battery; 3 MPPT Modules; EMS
Detail Link: View Details →