BIPV
Building Integrated Photovoltaic Solutions
Building integrated photovoltaics (BIPV) combines solar electricity generation with functional building elements. For developers, building owners and design teams, it offers a way to incorporate renewable energy into new construction and envelope refurbishment. The illustrated applications include ventilated roofs and tiles, skylights, curtain walls, cladding walls, shading devices and balconies. Each application is selected to suit the building's architecture, exposure and intended use. By coordinating these surfaces with an appropriately designed electrical system, the solution can support on-site electricity use while fulfilling the specified role of the building component.
Core Values
Generate Electricity On Site Integrate Solar Into Architecture Coordinate Energy and Envelope Design
Pain Points
- ●Limited space for solar generation: Roofs may already accommodate plant rooms, equipment or access routes, while surrounding land is unavailable. Owners seeking additional generation therefore need to evaluate other building surfaces, including facades and shading structures, without assuming every exposed area is suitable.
- ●Energy and architectural decisions made separately: When solar requirements are introduced after the envelope design is fixed, module layouts, visible cabling and support details may conflict with the intended appearance. Late changes can also complicate coordination between architectural, structural and electrical teams.
- ●Competing daylight and comfort requirements: Glazed roofs and facades need to balance daylight, views and solar exposure. Selecting a photovoltaic surface only for its electrical output can overlook the effect of its transparency, layout and shading on the spaces behind it.
- ●Complex construction and maintenance interfaces: Roofs, facades and balconies have different structural and weather-protection duties. Unclear responsibility for joints, fixings, cable routes and replacement access can leave gaps between the building design and the solar installation plan.
Suitable Applications
| Typical Setting | Electricity Use and Building Characteristics |
|---|---|
| Offices and mixed-use developments | Lighting, equipment and ventilation often create daytime demand. Roofs, facades and shading elements can be assessed alongside occupancy and architectural requirements. |
| Public and educational buildings | Teaching, administration and visitor activities may support daytime consumption. Atriums, skylights and prominent facades require coordinated daylight and appearance decisions. |
| Residential and hospitality buildings | Demand varies across the day and by occupancy. Roofs, balcony infill and selected facade areas may offer integration opportunities, subject to suitability and electricity allocation arrangements. |
Basic Conditions
1. Provide building drawings, site location, orientation, shading information and relevant electricity data. Identify whether the project is new construction or refurbishment, together with its architectural objectives.
2. Confirm that the supporting structure and proposed envelope assembly can accommodate the selected components. Assess weather protection, glazing or guarding functions where applicable, ventilation and maintenance access.
3. Establish feasible cable routes, electrical connection arrangements and responsibilities across the building and solar design teams. Confirm any proposed monitoring requirements separately.
System capacity, component selection and connection arrangements are determined through site assessment and coordinated design.
Solution Approach
Design Principles
The design places photovoltaic elements within selected roof, facade and external building assemblies. Architectural and electrical layouts are developed together so that the generating surfaces suit their construction functions. A typical electrical design would collect their DC output and use suitable conversion equipment to connect with the building's AC distribution. The precise connection arrangement remains subject to project design.
Application selection starts with the building's priorities. A project may focus on roof integration, use selected facade zones, or combine several applications. It does not need to incorporate every element shown. For refurbishment, the assessment should consider the condition and remaining service life of the existing envelope, as well as the practicality of replacing it. For new construction, module dimensions and visible joints can be coordinated with the architectural grid before detailing progresses.
- ●Generation and use strategy: Assess the generation profile of each selected surface against the building's demand. Different orientations and shading conditions may require separate electrical grouping. On-site consumption should be evaluated first; any export arrangement depends on the agreed grid connection. Storage, backup supply and island operation require separate designs.
- ●Configuration confirmation: Select component dimensions, appearance and electrical characteristics alongside the construction requirements of each application. Compare useful active area, shading, daylight needs, supporting details and replacement access. Calculate capacity from the selected products and layout rather than from the building's gross surface area.
System Integration and Connections
- ●Roof and skylight integration: Ventilated BIPV roof elements or tiles form part of the roof assembly, while BIPV skylights occupy glazed roof areas. Their integration details must address drainage, joints, support and any specified ventilation path. Skylight transparency and overhead glazing suitability require product-specific confirmation.
- ●Facade integration: BIPV curtain wall units connect with the facade framing, while BIPV cladding panels integrate with an appropriate wall support and envelope assembly. Their mechanical attachments and weather-management details depend on the chosen construction system. Neither application implies that the photovoltaic panel alone provides every required wall function.
- ●Shading and balcony integration: Photovoltaic shading elements attach to designed support structures. Fixings, edge details and cable routing must suit the location; any guarding function needs separate verification for the complete assembly.
- ●Electrical interfaces to be designed: Each selected application needs defined DC wiring, protection and connection to appropriate conversion equipment. The subsequent AC connection to building distribution must be documented in the project electrical drawings. Metering, monitoring and communication links are not depicted and should only be described as included after their scope is confirmed.
Product Composition
The following explains the roles of the components shown in the diagram. Actual supply scope, product models and functions are subject to the project design.
| Component | Role in the Solution |
|---|---|
| Ventilated BIPV roofs and BIPV tiles | Integrate solar generation into a roof covering assembly. The selected system must provide the specified roofing performance, with ventilation and drainage details coordinated where applicable. |
| BIPV skylights | Combine photovoltaic generation with a glazed roof application. Available daylight depends on the selected glazing and cell arrangement; overhead use requires confirmation of the complete assembly's suitability. |
| BIPV curtain walls | Incorporate generating elements into a curtain wall system. The modules and supporting facade design must jointly meet the intended enclosure and architectural functions. |
| BIPV cladding walls | Use photovoltaic elements as part of an external wall cladding assembly. Supports, joints and any cavity or weather-management provisions are selected for the actual wall construction. |
| BIPV shading devices | Place photovoltaic elements within external shading structures. Shading performance depends on their geometry and position, while electrical generation depends on available sunlight and the selected modules. |
| BIPV balconies | Integrate photovoltaic elements into the illustrated balcony perimeter. Suitability as infill or guarding depends on the specified product, fixing system and verified assembly performance. |
Building structures are integration interfaces, not an assumed part of the photovoltaic supply package.Inverters, cabling, protection, metering and monitoring require separate specification, which shall be further defined according to the actual project conditions.
Solution Value
Use More Suitable Building Surfaces
BIPV allows a project to assess generation opportunities across roofs, facades and selected external elements. This can broaden the options available where conventional roof space is constrained. The benefit depends on usable area and solar exposure: a large facade is not automatically a high-yield surface. Comparing orientations and shading before selecting applications helps concentrate investment on suitable locations.
Support On-Site Electricity Use
Electricity generated by the completed system can offset part of the building's grid purchases when production and consumption coincide. The amount used on site depends on the building's demand profile and the approved electrical arrangement. Economic assessment should account for generation, self-consumption, tariffs, installation, maintenance and eventual replacement costs. No fixed savings, export income or payback period is assumed.
Coordinate Architectural and Energy Functions
Designing photovoltaic elements together with the envelope allows teams to consider appearance, daylight, shading and construction interfaces at the same time. Where a BIPV component replaces a conventional building element, its cost and function can be compared with that alternative. This supports a project-specific assessment rather than treating all integration options as equivalent. Improvements in comfort, thermal performance or material use must be demonstrated by the selected assembly and design.
Project Case
Case Name: [To be provided]
Date: [Year / Month — to be provided]
System Size: [Installed PV capacity in kWp — to be provided]
Detail Link: View Details →
Find the Right BIPV Solution for Your Building
Share your project location, building drawings, roof and facade information, electricity demand profile and preferred architectural appearance. Include the construction stage and any requirements for daylight, shading or balcony integration. These inputs support an initial assessment of suitable application areas, product options and electrical connection needs.
Solutions
Contact Us
E-mail: info@onbipv.com
WeChat: +86 158 0002 4197
Whatsapp: +86 158 0002 4197











WhatsApp
Mail inquiry